Commit 95677a9a authored by Srinivas Pandruvada's avatar Srinivas Pandruvada Committed by Rafael J. Wysocki

PowerCap: Fix mode for energy counter

As per the documentation of powercap sysfs, energy_uj field is read only,
if it can't be reset. Currently it always allows write but will fail,
if there is no reset callback.
Changing mode field, to read only if there is no reset callback.
Signed-off-by: default avatarSrinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reported-by: default avatarDirk Brandewie <dirk.j.brandewie@intel.com>
Signed-off-by: default avatarRafael J. Wysocki <rafael.j.wysocki@intel.com>
parent 08ff4cbe
......@@ -377,9 +377,14 @@ static void create_power_zone_common_attributes(
if (power_zone->ops->get_max_energy_range_uj)
power_zone->zone_dev_attrs[count++] =
&dev_attr_max_energy_range_uj.attr;
if (power_zone->ops->get_energy_uj)
if (power_zone->ops->get_energy_uj) {
if (power_zone->ops->reset_energy_uj)
dev_attr_energy_uj.attr.mode = S_IWUSR | S_IRUGO;
else
dev_attr_energy_uj.attr.mode = S_IRUGO;
power_zone->zone_dev_attrs[count++] =
&dev_attr_energy_uj.attr;
}
if (power_zone->ops->get_power_uw)
power_zone->zone_dev_attrs[count++] =
&dev_attr_power_uw.attr;
......