drm/i915: Use CK505 as non-SSC source where available
When trying to use SSC on Ibex Peak without CK505, any non-SSC outputs (like VGA or TV) get broken. So, do not use SSC on Ibex Peak unless there is a CK505 available (as specified by the VBT). On Cougar Point, all clocking is internal, so SSC can always be used, and there will never be a CK505 available. This eliminates VGA shimmer on some Ironlake machines which have a CK505 clock source. References: https://bugzilla.kernel.org/show_bug.cgi?id=21742 References: https://bugs.freedesktop.org/show_bug.cgi?id=38750Signed-off-by: Keith Packard <keithp@keithp.com> Reviewed-by: Chris Wilson <chris@chris-wilson.co.uk>