clk: qcom: Properly change rates for ahbix clock
The ahbix clock can never be turned off in practice. To change the rates we need to switch the mux off the M/N counter to an always on source (XO), reprogram the M/N counter to get the rate we want and finally switch back to the M/N counter. Add a new ops structure for this type of clock so that we can set the rate properly. Fixes: c99e515a "clk: qcom: Add IPQ806X LPASS clock controller (LCC) driver" Tested-by: Kenneth Westfield <kwestfie@codeaurora.org> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>