Commit a5113ac8 authored by Laurent Pinchart's avatar Laurent Pinchart Committed by Hans Verkuil

media: docs: uAPI: Expand error documentation for invalid 'which' value

Multiple subdev ioctls that take a 'which' field do not document the
error returned when the field has an invalid value. Expand the
documentation to fix this.
Signed-off-by: default avatarLaurent Pinchart <laurent.pinchart@ideasonboard.com>
Signed-off-by: default avatarHans Verkuil <hverkuil-cisco@xs4all.nl>
parent 2b455a55
......@@ -107,8 +107,7 @@ appropriately. The generic error codes are described at the
:ref:`Generic Error Codes <gen-errors>` chapter.
EINVAL
The struct
:c:type:`v4l2_subdev_frame_interval_enum`
``pad`` references a non-existing pad, one of the ``code``,
``width`` or ``height`` fields are invalid for the given pad or the
``index`` field is out of bounds.
The struct :c:type:`v4l2_subdev_frame_interval_enum` ``pad`` references a
non-existing pad, the ``which`` field has an unsupported value, one of the
``code``, ``width`` or ``height`` fields are invalid for the given pad, or
the ``index`` field is out of bounds.
......@@ -126,7 +126,6 @@ appropriately. The generic error codes are described at the
:ref:`Generic Error Codes <gen-errors>` chapter.
EINVAL
The struct
:c:type:`v4l2_subdev_frame_size_enum`
``pad`` references a non-existing pad, the ``code`` is invalid for
the given pad or the ``index`` field is out of bounds.
The struct :c:type:`v4l2_subdev_frame_size_enum` ``pad`` references a
non-existing pad, the ``which`` field has an unsupported value, the ``code``
is invalid for the given pad, or the ``index`` field is out of bounds.
......@@ -158,7 +158,6 @@ appropriately. The generic error codes are described at the
:ref:`Generic Error Codes <gen-errors>` chapter.
EINVAL
The struct
:c:type:`v4l2_subdev_mbus_code_enum`
``pad`` references a non-existing pad, or the ``index`` field is out
of bounds.
The struct :c:type:`v4l2_subdev_mbus_code_enum` ``pad`` references a
non-existing pad, the ``which`` field has an unsupported value, or the
``index`` field is out of bounds.
......@@ -140,8 +140,9 @@ ENOSPC
all the available routes the subdevice exposes.
EINVAL
The sink or source pad identifiers reference a non-existing pad, or reference
pads of different types (ie. the sink_pad identifiers refers to a source pad).
The sink or source pad identifiers reference a non-existing pad or reference
pads of different types (ie. the sink_pad identifiers refers to a source
pad), or the ``which`` field has an unsupported value.
E2BIG
The application provided ``num_routes`` for ``VIDIOC_SUBDEV_S_ROUTING`` is
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment