arm64: signal: Force SIGKILL for unknown signals in force_signal_inject
For signals other than SIGKILL or those with siginfo_layout(signal, code) == SIL_FAULT then force_signal_inject does not initialise the siginfo_t properly. Since the signal number is determined solely by the caller, simply WARN on unknown signals and force to SIGKILL. Reported-by: Dave Martin <Dave.Martin@arm.com> Signed-off-by: Will Deacon <will.deacon@arm.com>
Showing
Please register or sign in to comment