staging: comedi: adv_pci1710: Fix endian problem for AI command data
The analog input subdevice supports Comedi asynchronous commands that use Comedi's 16-bit sample format. However, the calls to `comedi_buf_write_samples()` are passing the address of a 32-bit integer variable. On bigendian machines, this will copy 2 bytes from the wrong end of the 32-bit value. Fix it by changing the type of the variables holding the sample value to `unsigned short`. The type of the `val` parameter of `pci1710_ai_read_sample()` is changed to `unsigned short *` accordingly. The type of the `val` variable in `pci1710_ai_insn_read()` is also changed to `unsigned short` since its address is passed to `pci1710_ai_read_sample()`. Fixes: a9c3a015 ("staging: comedi: adv_pci1710: use comedi_buf_write_samples()") Cc: <stable@vger.kernel.org> # 4.0+ Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Link: https://lore.kernel.org/r/20210223143055.257402-4-abbotti@mev.co.ukSigned-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>