Commit bc40b5e3 authored by Srinivas Pandruvada's avatar Srinivas Pandruvada Committed by Zhang Rui

thermal: Intel SoC DTS thermal

In the Intel SoCs like Bay Trail, there are 2 additional digital temperature
sensors(DTS), in addition to the standard DTSs in the core. Also they support
4 programmable thresholds, out of which two can be used by OSPM. These
thresholds can be used by OSPM thermal control. Out of these two thresholds,
one is used by driver and one user mode can change via thermal sysfs to get
notifications on threshold violations.

The driver defines one critical trip points, which is set to TJ MAX - offset.
The offset can be changed via module parameter (default 5C). Also it uses
one of the thresholds to get notification for this temperature violation.
This is very important for orderly shutdown as the many of these devices don't
have ACPI thermal zone, and expects that there is some other thermal control
mechanism present in OSPM. When a Linux distro is used without additional
specialized thermal control program, BIOS can do force shutdown when thermals
are not under control. When temperature reaches critical, the Linux thermal
core will initiate an orderly shutdown.
Signed-off-by: default avatarSrinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: default avatarZhang Rui <rui.zhang@intel.com>
parent d6d211db
......@@ -222,6 +222,18 @@ config ACPI_INT3403_THERMAL
the Intel Thermal Daemon can use this information to allow the user
to select his laptop to run without turning on the fans.
config INTEL_SOC_DTS_THERMAL
tristate "Intel SoCs DTS thermal driver"
depends on X86 && IOSF_MBI
help
Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
temperature sensor (DTS). These SoCs have two additional DTSs in
addition to DTSs on CPU cores. Each DTS will be registered as a
thermal zone. There are two trip points. One of the trip point can
be set by user mode programs to get notifications via Linux thermal
notification methods.The other trip is a critical trip point, which
was set by the driver based on the TJ MAX temperature.
menu "Texas Instruments thermal drivers"
source "drivers/thermal/ti-soc-thermal/Kconfig"
endmenu
......
......@@ -29,5 +29,6 @@ obj-$(CONFIG_IMX_THERMAL) += imx_thermal.o
obj-$(CONFIG_DB8500_CPUFREQ_COOLING) += db8500_cpufreq_cooling.o
obj-$(CONFIG_INTEL_POWERCLAMP) += intel_powerclamp.o
obj-$(CONFIG_X86_PKG_TEMP_THERMAL) += x86_pkg_temp_thermal.o
obj-$(CONFIG_INTEL_SOC_DTS_THERMAL) += intel_soc_dts_thermal.o
obj-$(CONFIG_TI_SOC_THERMAL) += ti-soc-thermal/
obj-$(CONFIG_ACPI_INT3403_THERMAL) += int3403_thermal.o