net: dsa: sja1105: fix broken connection with the sja1110 tagger
The driver was incorrectly converted assuming that "sja1105" is the only tagger supported by this driver. This results in SJA1110 switches failing to probe: sja1105 spi1.0: Unable to connect to tag protocol "sja1110": -EPROTONOSUPPORT sja1105: probe of spi1.2 failed with error -93 Add DSA_TAG_PROTO_SJA1110 to the list of supported taggers by the sja1105 driver. The sja1105_tagger_data structure format is common for the two tagging protocols. Fixes: c79e8486 ("net: dsa: tag_sja1105: convert to tagger-owned data") Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>