Fix VIA-based TB/Decrementer calibration , previously it wouldn't work

properly with HZ != 100, causing tb_to_us to be wrong and gettimeofday()
to return strangely "off" results
parent b87d0087
......@@ -166,7 +166,7 @@ via_calibrate_decr(void)
{
struct device_node *vias;
volatile unsigned char *via;
int count = VIA_TIMER_FREQ_6 / HZ;
int count = VIA_TIMER_FREQ_6 / 100;
unsigned int dstart, dend;
vias = find_devices("via-cuda");
......@@ -196,7 +196,7 @@ via_calibrate_decr(void)
;
dend = get_dec();
tb_ticks_per_jiffy = (dstart - dend) / 6;
tb_ticks_per_jiffy = (dstart - dend) / (6 * (HZ/100));
tb_to_us = mulhwu_scale_factor(dstart - dend, 60000);
printk(KERN_INFO "via_calibrate_decr: ticks per jiffy = %u (%u ticks)\n",
......@@ -260,7 +260,9 @@ pmac_calibrate_decr(void)
* calibration. That's better since the VIA itself seems
* to be slightly off. --BenH
*/
if (!machine_is_compatible("MacRISC2"))
if (!machine_is_compatible("MacRISC2") &&
!machine_is_compatible("MacRISC3") &&
!machine_is_compatible("MacRISC4"))
if (via_calibrate_decr())
return;
......