SGI Altix mmtimer: allow larger number of timers per node
The purpose of this patch to the SGI Altix specific mmtimer (posix timer) driver is to allow a virtually infinite number of timers to be set per node. Timers will now be kept on a sorted per-node list and a single node-based hardware comparator is used to trigger the next timer. [akpm@linux-foundation.org: mark things static] [akpm@linux-foundation.org: fix warning] Signed-off-by: Dimitri Sivanich <sivanich@sgi.com> Cc: "Luck, Tony" <tony.luck@intel.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>