Commit d9070fdb authored by Boris Brezillon's avatar Boris Brezillon Committed by Thierry Reding

regulator: pwm: Retrieve correct voltage

The continuous PWM voltage regulator is caching the voltage value in
the ->volt_uV field. While most of the time this value should reflect the
real voltage, sometime it can be sightly different if the PWM device
rounded the set_duty_cycle request.
Moreover, this value is not valid until someone has modified the regulator
output.

Remove the ->volt_uV field and always rely on the PWM state to calculate
the regulator output.
Signed-off-by: default avatarBoris Brezillon <boris.brezillon@free-electrons.com>
Reviewed-by: default avatarBrian Norris <briannorris@chromium.org>
Tested-by: default avatarBrian Norris <briannorris@chromium.org>
Tested-by: default avatarHeiko Stuebner <heiko@sntech.de>
Acked-by: default avatarMark Brown <broonie@kernel.org>
Signed-off-by: default avatarThierry Reding <thierry.reding@gmail.com>
parent 87248991
......@@ -37,9 +37,6 @@ struct pwm_regulator_data {
int state;
/* Continuous voltage */
int volt_uV;
/* Enable GPIO */
struct gpio_desc *enb_gpio;
};
......@@ -148,8 +145,13 @@ static int pwm_regulator_is_enabled(struct regulator_dev *dev)
static int pwm_regulator_get_voltage(struct regulator_dev *rdev)
{
struct pwm_regulator_data *drvdata = rdev_get_drvdata(rdev);
int min_uV = rdev->constraints->min_uV;
int diff = rdev->constraints->max_uV - min_uV;
struct pwm_state pstate;
return drvdata->volt_uV;
pwm_get_state(drvdata->pwm, &pstate);
return min_uV + pwm_get_relative_duty_cycle(&pstate, diff);
}
static int pwm_regulator_set_voltage(struct regulator_dev *rdev,
......@@ -176,8 +178,6 @@ static int pwm_regulator_set_voltage(struct regulator_dev *rdev,
return ret;
}
drvdata->volt_uV = min_uV;
if ((ramp_delay == 0) || !pwm_regulator_is_enabled(rdev))
return 0;
......