Commit e1fae554 authored by Viresh Kumar's avatar Viresh Kumar Committed by Eduardo Valentin

thermal: cpu_cooling: don't iterate over all allowed_cpus to update cpufreq policy

All CPUs present in 'allowed_cpus' share the same 'struct cpufreq_policy'
structure and so calling cpufreq_update_policy() for each of them doesn't make
sense.
Signed-off-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: default avatarEduardo Valentin <edubezval@gmail.com>
parent 405fb825
......@@ -285,11 +285,10 @@ static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level)
static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
unsigned long cooling_state)
{
unsigned int cpuid, clip_freq;
unsigned int clip_freq;
struct cpumask *mask = &cpufreq_device->allowed_cpus;
unsigned int cpu = cpumask_any(mask);
/* Check if the old cooling action is same as new cooling action */
if (cpufreq_device->cpufreq_state == cooling_state)
return 0;
......@@ -301,10 +300,8 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
cpufreq_device->cpufreq_state = cooling_state;
cpufreq_device->cpufreq_val = clip_freq;
for_each_cpu(cpuid, mask) {
if (is_cpufreq_valid(cpuid))
cpufreq_update_policy(cpuid);
}
if (is_cpufreq_valid(cpu))
cpufreq_update_policy(cpu);
return 0;
}
......