Commit e8e61235 authored by Zbigniew Lukwinski's avatar Zbigniew Lukwinski Committed by Guenter Roeck

docs: hwmon: Add attributes to report rated values

New attributes (rated_min/rated_max) are being added the hwmon ABI.
They are needed to cover rated values documented by PMBus
specification:
PMBus Power System Mgt Protocol Specification - Part II – Revision 1.3.1,
chapters: 22.3.1 - 22.3.10, 22.3.15
Signed-off-by: default avatarZbigniew Lukwinski <zbigniew.lukwinski@linux.intel.com>
Link: https://lore.kernel.org/r/1596224237-32280-2-git-send-email-zbigniew.lukwinski@linux.intel.comSigned-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent 18360b33
......@@ -241,6 +241,20 @@ Voltages
Affects the way the driver calculates the CPU core reference
voltage from the vid pins.
`in[0-*]_rated_min`
Minimum rated voltage.
Unit: millivolt
RO
`in[0-*]_rated_max`
Maximum rated voltage.
Unit: millivolt
RO
Also see the Alarms section for status flags associated with voltages.
......@@ -574,6 +588,20 @@ Temperatures
RW
`temp[1-*]_rated_min`
Minimum rated temperature.
Unit: millidegree Celsius
RO
`temp[1-*]_rated_max`
Maximum rated temperature.
Unit: millidegree Celsius
RO
Some chips measure temperature using external thermistors and an ADC, and
report the temperature measurement as a voltage. Converting this voltage
back to a temperature (or the other way around for limits) requires
......@@ -664,6 +692,20 @@ Currents
RW
`curr[1-*]_rated_min`
Minimum rated current.
Unit: milliampere
RO
`curr[1-*]_rated_max`
Maximum rated current.
Unit: milliampere
RO
Also see the Alarms section for status flags associated with currents.
*****
......@@ -830,6 +872,20 @@ Power
RW
`power[1-*]_rated_min`
Minimum rated power.
Unit: microWatt
RO
`power[1-*]_rated_max`
Maximum rated power.
Unit: microWatt
RO
Also see the Alarms section for status flags associated with power readings.
******
......@@ -877,6 +933,20 @@ Humidity
RW
`humidity[1-*]_rated_min`
Minimum rated humidity.
Unit: milli-percent (per cent mille, pcm)
RO
`humidity[1-*]_rated_max`
Maximum rated humidity.
Unit: milli-percent (per cent mille, pcm)
RO
******