power: supply: olpc_battery: correct the temperature units
According to [1] and [2], the temperature values are in tenths of degree Celsius. Exposing the Celsius value makes the battery appear on fire: $ upower -i /org/freedesktop/UPower/devices/battery_olpc_battery ... temperature: 236.9 degrees C Tested on OLPC XO-1 and OLPC XO-1.75 laptops. [1] include/linux/power_supply.h [2] Documentation/power/power_supply_class.txt Fixes: fb972873 ("[BATTERY] One Laptop Per Child power/battery driver") Cc: stable@vger.kernel.org Signed-off-by: Lubomir Rintel <lkundrak@v3.sk> Acked-by: Pavel Machek <pavel@ucw.cz> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>