Commit f60acad3 authored by Josef Bacik's avatar Josef Bacik Committed by David Sterba

btrfs: move btrfs_print_data_csum_error into inode.c

This isn't used outside of inode.c, there's no reason to define it in
btrfs_inode.h. Drop the inline and add __cold as it's for errors that
are not in any hot path.
Reviewed-by: default avatarQu Wenruo <wqu@suse.com>
Reviewed-by: default avatarJohannes Thumshirn <johannes.thumshirn@wdc.com>
Signed-off-by: default avatarJosef Bacik <josef@toxicpanda.com>
Reviewed-by: default avatarDavid Sterba <dsterba@suse.com>
Signed-off-by: default avatarDavid Sterba <dsterba@suse.com>
parent f1e5c618
......@@ -410,30 +410,4 @@ static inline void btrfs_inode_split_flags(u64 inode_item_flags,
/* Array of bytes with variable length, hexadecimal format 0x1234 */
#define CSUM_FMT "0x%*phN"
#define CSUM_FMT_VALUE(size, bytes) size, bytes
static inline void btrfs_print_data_csum_error(struct btrfs_inode *inode,
u64 logical_start, u8 *csum, u8 *csum_expected, int mirror_num)
{
struct btrfs_root *root = inode->root;
const u32 csum_size = root->fs_info->csum_size;
/* Output minus objectid, which is more meaningful */
if (root->root_key.objectid >= BTRFS_LAST_FREE_OBJECTID)
btrfs_warn_rl(root->fs_info,
"csum failed root %lld ino %lld off %llu csum " CSUM_FMT " expected csum " CSUM_FMT " mirror %d",
root->root_key.objectid, btrfs_ino(inode),
logical_start,
CSUM_FMT_VALUE(csum_size, csum),
CSUM_FMT_VALUE(csum_size, csum_expected),
mirror_num);
else
btrfs_warn_rl(root->fs_info,
"csum failed root %llu ino %llu off %llu csum " CSUM_FMT " expected csum " CSUM_FMT " mirror %d",
root->root_key.objectid, btrfs_ino(inode),
logical_start,
CSUM_FMT_VALUE(csum_size, csum),
CSUM_FMT_VALUE(csum_size, csum_expected),
mirror_num);
}
#endif
......@@ -125,6 +125,32 @@ static struct extent_map *create_io_em(struct btrfs_inode *inode, u64 start,
u64 ram_bytes, int compress_type,
int type);
static void __cold btrfs_print_data_csum_error(struct btrfs_inode *inode,
u64 logical_start, u8 *csum, u8 *csum_expected, int mirror_num)
{
struct btrfs_root *root = inode->root;
const u32 csum_size = root->fs_info->csum_size;
/* Output without objectid, which is more meaningful */
if (root->root_key.objectid >= BTRFS_LAST_FREE_OBJECTID) {
btrfs_warn_rl(root->fs_info,
"csum failed root %lld ino %lld off %llu csum " CSUM_FMT " expected csum " CSUM_FMT " mirror %d",
root->root_key.objectid, btrfs_ino(inode),
logical_start,
CSUM_FMT_VALUE(csum_size, csum),
CSUM_FMT_VALUE(csum_size, csum_expected),
mirror_num);
} else {
btrfs_warn_rl(root->fs_info,
"csum failed root %llu ino %llu off %llu csum " CSUM_FMT " expected csum " CSUM_FMT " mirror %d",
root->root_key.objectid, btrfs_ino(inode),
logical_start,
CSUM_FMT_VALUE(csum_size, csum),
CSUM_FMT_VALUE(csum_size, csum_expected),
mirror_num);
}
}
/*
* btrfs_inode_lock - lock inode i_rwsem based on arguments passed
*
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!