ASoC: Intel: bxt: Move codec sysclk config to codec_init function
The MCLK for DA7219 does not change in this platform, but is currently being configured everytime as part of the platform_clock event handler for DAPM. The upshot of this is that we have unnecessary calls to this function, and it also means that if a stream hasn't yet been started, DA7219 driver does not have the correct MCLK rates programmed and so the HP detection feature does not operate as expected. This patch rectifies this issue by moving the sysclk call to codec_init function so it's only called once at initialisation. Signed-off-by: Adam Thomson <Adam.Thomson.Opensource@diasemi.com> Acked-by: Sathyanarayana Nujella <sathyanarayana.nujella@intel.com> Signed-off-by: Mark Brown <broonie@kernel.org>