- 18 Jun, 2012 5 commits
-
-
Mark Brown authored
Due to the lack of a generic clock API we'd had the 32kHz clock in the regulator driver but this is definitely a Linux-specific thing and now we have a clock API hopefully the code can be moved elsewhere. Try to avoid getting DTs deployed relying on the 32kHz clock by removing it from the bindings, grep seems to tell me it's not currently used anyway. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Mark Brown authored
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
This change makes it possible to set ramp_delay with 0.xxx mV/uS without truncation issue. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
For table based mapping, we can calculate voltage difference by below equation: abs(rdev->desc->volt_table[new_selector] - rdev->desc->volt_table[old_selector]) Thus we can make regulator_set_voltage_time_sel work for table based mapping. regulator_set_voltage_time_sel() only supports linear or table based mapping. In case it is misused, also warn if neither linear nor table based mapping is used with regulator_set_voltage_time_sel(). Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 17 Jun, 2012 15 commits
-
-
Yadwinder Singh Brar authored
For some hardwares ramp_delay for BUCKs is a configurable parameter which can be configured through DT or board file.This patch adds ramp_delay to regulator constraints and allow user to configure it for regulators which supports this feature, through DT or board file. It will provide two ways of setting the ramp_delay for a regulator: First, by setting it as constraints in board file(for configurable regulators) and set_machine_constraints() will take care of setting it on hardware by calling(the provided) .set_ramp_delay() operation(callback). Second, by setting it as data in regulator_desc(as fixed/default ramp_delay rate) for a regulator in driver. regulator_set_voltage_time_sel() will give preference to constraints->ramp_delay while reading ramp_delay rate for regulator. Similarly users should also take care accordingly while refering ramp_delay rate(in case of implementing their private .set_voltage_time_sel() callbacks for different regulators). [Rewrote subject for 80 columns -- broonie] Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
The min_uV and max_uV are not really used in the code and misleading because the min_uV and max_uV settings does not match the value in the voltage table. For example, we have static const unsigned int ldo_vaux3_voltages[] = { 1200000, 1500000, 1800000, 2100000, 2500000, 2750000, 2790000, 2910000, }; With below min_uV/max_uV settings for AB8500_LDO_AUX3. .min_uV = 1100000, .max_uV = 3300000, The min_uV/max_uV for AB8500_LDO_AUX3 seems copy-paste from AB8500_LDO_AUX2 and is wrong. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Also removes set_voltage_time_sel callback from ab8500_regulator_fixed_ops because the voltage won't change. ( And ab8500_regulator_fixed_ops does not implement get_voltage_sel so set_voltage_time_sel won't be called ) Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
The voltage range checking should be to ensure mc13xxx_regulators[id].voltages[0] falls with min_uV and max_uV. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
For linear mappings, we can use below equation to get the voltage difference between new_selector and old_selector: abs(new_selector - old_selector) * rdev->desc->uV_step Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
For fixed voltage, the n_voltages should be 1 rather than 0. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Reuse map_voltage() to get the selector of a given uV. Then we can remove wm8350_ldo_mvolts_to_val() and wm8350_dcdc_mvolts_to_val(). Also remove unused wm8350_dcdc_val_to_mvolts() function. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Call wm8350_ldo_list_voltage() instead of open code to verify selected voltage falls within specified range. Use wm8350_ldo_list_voltage() here is less error prone. wm8350_ldo_val_to_mvolts() is only used in wm8350_ldo_list_voltage now, so remove it and move the implementation to wm8350_ldo_list_voltage(). This patch also include below small changes in wm8350_ldo_map_voltage: 1. wm8350_ldo_map_voltage() returns selector, thus rename variable mV to sel. 2. Use DIV_ROUND_UP macro to calculate selector. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 13 Jun, 2012 6 commits
-
-
Axel Lin authored
This patch converts .is_enabled and .get_voltage_sel to regulator_is_enabled_regmap and regulator_get_voltage_sel_regmap. For .enable, .disable, and .set_voltage_sel, the write protect level is either 1 or 2. So we cannot use regulator_[enable|disable|set_voltage_sel]_regmap. Now we store the enable reg/mask and vsel reg/mask in regulator_desc, so we can remove enable_mask, set_vout_reg, and set_vout_mask from struct tps_info. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Adjust the equation for selector >= 15 for better readability. The equation "1700000 + ((selector - 15) * 100000)" can be interpreted by: Starting from selector 15: Steps of 100mV from 1700mV Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Sangbeom Kim authored
To apply delay time for voltage change, replace s5m8767_set_voltage with s5m8767_set_voltage_sel. Signed-off-by: Sangbeom Kim <sbkim73@samsung.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Call wm8400_ldo_list_voltage() instead of open code to verify selected voltage falls within specified range. Use wm8400_ldo_list_voltage() here is less error prone. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Sangbeom Kim authored
As s5m8767a is revisioned, remove unnecessary buck 2,3,4 initialization routine. Signed-off-by: Sangbeom Kim <sbkim73@samsung.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 11 Jun, 2012 7 commits
-
-
Axel Lin authored
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV. The unit of ramp_delay is mV/us. Current code multiples 1000 at wrong place. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV. The unit of ramp_rate is mV/us. Thus 1000 should be multiplied. Signed-off-by: Axel Lin <axel.lin@gmail.com> Reviewed-by: Yadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Yadwinder Singh Brar authored
This patch adds regulator_set_voltage_time_sel(), to move into core, the commonly used code by drivers to provide the .set_voltage_time_sel callback. It will also allow us to configure different ramp delay for different regulators easily. Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
If this driver only works when pdata->num_regulators == MAX77686_REGULATORS, let's check it earlier. Also remove unused num_regulators from struct max77686_data. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
isl_fixed_ops does not implement set_voltage_sel callback, adding map_voltage here is misleading. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 08 Jun, 2012 2 commits
-
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 07 Jun, 2012 5 commits
-
-
Axel Lin authored
Also adds tps6586x_ldo0_voltages mapping table for LDO0, so we can remove the hack in tps6586x_list_voltage() and convert it to regulator_list_voltage_table. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
It's a little bit hard to read that the "else" case means id == PALMAS_REG_SMPS10. if (id != PALMAS_REG_SMPS10){ do something for the cases id != PALMAS_REG_SMPS10; } else { do something for the case id == PALMAS_REG_SMPS10; } This patch changes above syntax to switch statement. Signed-off-by: Axel Lin <axel.lin@gmail.com> Acked-by: Graeme Gregory <gg@slimlogic.co.uk> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Current code actually clears more bits than PALMAS_SMPS12_CTRL_MODE_ACTIVE_MASK bits. Signed-off-by: Axel Lin <axel.lin@gmail.com> Acked-by: Graeme Gregory <gg@slimlogic.co.uk> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
For linear mappings, we can use below equation to get the voltage difference between new_selector and old_selector: abs(new_selector - old_selector) * rdev->desc->uV_step Signed-off-by: Axel Lin <axel.lin@gmail.com> Acked-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-