1. 27 Apr, 2009 1 commit
    • Peter Jones's avatar
      [SCSI] sr: report more accurate drive status after closing the tray. · 96bcc722
      Peter Jones authored
      So, what's happening here is that the drive is reporting a sense of
      2/4/1 ("logical unit is becoming ready") from sr_test_unit_ready(), and
      then we ask for the media event notification before checking that result
      at all.  The check_media_event_descriptor() call isn't getting a check
      condition, but it's also reporting that the tray is closed and that
      there's no media.  In actuality it doesn't yet know if there's media or
      not, but there's no way to express that in the media event status field.
      
      My current thought is that if it told us the device isn't yet ready, we
      should return that immediately, since there's nothing that'll tell us
      any more data than that reliably:
      Signed-off-by: default avatarJames Bottomley <James.Bottomley@HansenPartnership.com>
      96bcc722
  2. 26 Apr, 2009 11 commits
  3. 24 Apr, 2009 28 commits