    • Brandon Wyman's avatar
      hwmon: (pmbus) Add Vin unit off handling · a5436af5
      Brandon Wyman authored
      If there is an input undervoltage fault, reported in STATUS_INPUT
      command response, there is quite likely a "Unit Off For Insufficient
      Input Voltage" condition as well.
      
      Add a constant for bit 3 of STATUS_INPUT. Update the Vin limit
      attributes to include both bits in the mask for clearing faults.
      
      If an input undervoltage fault occurs, causing a unit off for
      insufficient input voltage, but the unit is off bit is not cleared, the
      STATUS_WORD will not be updated to clear the input fault condition.
      Including the unit is off bit (bit 3) allows for the input fault
      condition to completely clear.
      Signed-off-by: default avatarBrandon Wyman <bjwyman@gmail.com>
      Link: https://lore.kernel.org/r/20220317232123.2103592-1-bjwyman@gmail.com
      Fixes: b4ce237b ("hwmon: (pmbus) Introduce infrastructure to detect sensors and limit registers")
      [groeck: Dropped unnecessary ()]
      Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>