Krzysztof Kozlowski authored
Thermal core could not read the temperature after registering the thermal sensor with thermal_zone_of_sensor_register() because the driver was not yet initialized. The call trace looked like: exynos_tmu_probe() thermal_zone_of_sensor_register() of_thermal_set_mode() thermal_zone_device_update() exynos_get_temp() if (!data->tmu_read) return -EINVAL; exynos_map_dt_data() data->tmu_read = ... This produced an error in dmesg: thermal thermal_zone0: failed to read out thermal zone (-22) Register the thermal_zone_device later, after parsing Device Tree and enabling necessary clocks, but before calling exynos_tmu_initialize() which uses the registered thermal_zone_device. Reviewed-by: Alim Akhtar <alim.akhtar@samsung.com> Tested-by: Alim Akhtar <alim.akhtar@samsung.com> Acked-by: Lukasz Majewski <l.majewski@samsung.com> Tested-by: Lukasz Majewski <l.majewski@samsung.com> Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Fixes: 3b6a1a80 ("thermal: samsung: core: Exynos TMU rework to use device tree for configuration") Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
9e4249b4