sky2: fix hang on shutdown (and other irq issues)
There are several problems with recent change to how IRQ's are setup. * synchronize_irq in sky2_shutdown would hang because there was no IRQ setup. * when device was set to down, some IRQ bits left enabled so a hardware error would produce IRQ with no handler * quick link on Optima chip set was enabled without handler * suspend/resume would leave IRQ on with no handler if device was down Signed-off-by: Stephen Hemminger <shemminger@vyatta.com> Signed-off-by: David S. Miller <davem@davemloft.net>